Zuercher Technik AG (Switzerland) – Tank Blanketing Valves :

Inertization Process

1️⃣ Cycle 1

  • Close V1, open V2 until pressure reaches approx. –800 mbarg (= 200 mbar abs).

  • Then close V2, open V1, and fill the missing volume with nitrogen.

  • Dilution ratio: 1:5 → Residual oxygen: ~4%

2️⃣ Cycle 2

  • Repeat the same process.

  • Dilution ratio: 1:5 → Residual oxygen: ~0.8%

After the inertization process, the system automatically switches to blanketing mode.

  • When pressure falls below 15 mbarg, the pressure reducer feeds nitrogen into the tank.

  • When pressure exceeds 40 mbarg, the safety valve releases the excess gas.