H2S Analyzer

The Applied Analytics OMA H2S Analyzer measures real-time H2S concentration in liquid or gas process by monitoring the UV-Vis absorbance in a continuously drawn sample. The OMA H2S Analyzer can analyze hydrogen sulfide in natural gas, crude oil, water, biogas and landfill gas, feed forward, lean/rich amine, stripped sour water, wastewater, syngas, flare gas, flue gas, hydrogen recycle gas, scrubber outlet gas, LPG and more.

Harvesting this rich data, the OMA H2S Analyzer isolates the H2S absorbance curve and provides a real-time value for H2S concentration in your process.

H2S occurs abundantly in the world’s fossil fuel reserves and also forms as a by-product in various industrial and biological processes. In order to produce clean-burning fuels, prevent acid rain, protect pipelines and equipment from corrosion, and — most importantly — protect workers from imminent disasters, H2S levels are highly regulated using scrubbers, scavengers, sulfur recovery units, and other removal technologies.

To properly control the level of H2S in fuel, wastewater, or emissions, you need a reliable method of measuring the H2S concentration. Since safety is a major concern, only highly proven solutions are considered. For many years, that meant that customers were stuck with archaic paper tape technology, a maintenance headache with toxic consumables and frequent moving-part hardware failures.

With thousands of units shipped, the OMA H2S Analyzer has been deployed for a wide range of applications across various industries:

  • acid gas
  • biogas
  • catalyst pre-sulfiding
  • CEMS
  • CO2 recycle
  • cooling water
  • crude oil
  • feed forward
  • flare gas
  • flue gas
  • fuel gas
  • gasoline
  • hydrogen recycle
  • landfill gas
  • lean amine
  • LPG
  • natural gas
  • petroleum
  • pipeline gas
  • propane
  • rich amine
  • sales gas
  • scrubber outlet
  • seawater
  • stack gas
  • stripped sour water
  • sulfur pit

H2S Absorbance Spectrum

To measure H2S concentration, the OMA detects the distinctive absorbance curve of pure H2S and mathematically isolates this structure from the total sample absorbance. In accordance with Beer-Lambert Law, the OMA correlates the height of this curve directly to real-time hydrogen sulfide concentration.

Sampling: H2S Analyzer

The OMA is built for direct analysis of the hot/wet sample, thus simplifying the scope of the sample system and retaining high sample integrity. From our vast experience in sampling design, we know that applications can be similar but are rarely identical. For this reason, we design and build sample conditioning systems on a project basis, working from the process to the drawing board.

General

Measurement Principle

Dispersive ultraviolet-visible (UV-Vis) absorbance spectrophotometry

Detector

nova II™ UV-Vis diode array spectrophotometer

Spectral Range

200-800 nm

Light Source

Pulsed xenon lamp (average 5 year lifespan)

Signal Transmission

600 μm core 1.8 meter fiber optic cables
Other lengths available

Path Length

Application-dependent

Sample Conditioning

Custom design per application

Analyzer Calibration

If possible, analyzer is factory calibrated with certified calibration fluids; no re-calibration required after initial calibration; measurement normalized by Auto Zero

Reading Verification

Simple verification with samples and self-check diagnostic

Human Machine Interface

Industrial controller with touch-screen LCD display running ECLIPSE™ Software

Data Storage

Solid State Drive

OPERATING CONDITIONS

Analyzer Environment

Indoor/Outdoor (no shelter required)

Ambient Temperature

Standard: 0 to 35 °C (32 to 95 °F)
Optional: -20 to 55 °C (-4 to 131 °F)
To avoid radiational heating, use of a sunshade is recommended for systems installed in direct sunlight.

Sample Temperature

Standard: -20 to 70 °C (-4 to 158 °F)
Optional: up to 150 °C (302 °F) with cooling extensions
Contact AAI for temperatures above 150 °C (302°F)

Sample Pressure

Using standard flow cell: 206 bar (3000 psi)

UTILITIES

Electrical

85 to 264 VAC 47 to 63 Hz

Power Consumption

45 watts

OUTPUTS

Standard Outputs

1x galvanically isolated 4-20mA analog output per measured analyte(up to 3; additional available by upgrade)
2x digital outputs for fault and SCS control

Optional Outputs

Modbus TCP/IP; RS-232; RS-485; Fieldbus; Profibus; HART;

Performance

H2S Accuracy in Liquid

Example ranges below. Custom ranges available.
0-100 mg/L: ±1% full scale or 1 mg/L*
*Whichever larger.

H2S Accuracy in Gas

Example ranges below. Custom ranges available. Accuracy may be higher at higher pressure.
0-10 ppm (@1 bar): ±1 ppm (Increased pressure will yield increased accuracy); ±0.2 ppm (@5 bar)
0-100 ppm: ±1% full scale or 1 ppm*
0-10,000 ppm: ±1% full scale
0-100%: ±1% full scale
*Whichever larger.

Certifications

Standard Design

General Purpose

Available Options

ATEX, IECEx, EAC, PESO, JPN, KTL

Please inquire with your sales representative for additional certifications (CSA, FM etc.).